MagVAR MVLM Known Bugs and Limitations
-
Output files in Excel 2013 will have two different formatting (bold/not bold) for the date column on the 'Data' sheet of the file. This is merely a formatting issue and does not affect any of the calculated data.
-
Output files in Excel 2013 will have two different formatting (bold/not bold) for the date column on the 'Data' sheet of the file. This is merely a formatting issue and does not affect any of the calculated data.
MagVAR IFR Calculator (MVLM) 5.0
-
If a file is processed with QC option, the summary sheet of the report displays incorrect units for Gtotal. The sheet displays the units as m/s2 instead of mill-g.
-
Output files in Excel 2013 will have two different formatting (bold/not bold) for the date column on the 'Data' sheet of the file. This is merely a formatting issue and does not affect any of the calculated data.
MagVAR IFR Calculator (MVLM) 4.2.1.2
-
There is a new version of the Well Architect software, and the file format seems to have changed. MagVar is working on modifying our calculator to accommodate this. In the meantime, please use this workaround:
- Open the file with the new format (e.g. HA-SANFORD-152-96-1819H-2 (5-22-15) IFR) in NotePad or WordPad
- Open an “Example” file which is in the old format in NotePad or WordPad (this is part of the download when you download the entire package)
- Copy the entire contents (select all) from the new format file (e.g. HA-SANFORD-152-96-1819H-2 (5-22-15) IFR) and paste it into the old format file (e.g. Example)
- Save the old format file (e.g. Example)
- Use this old format file (e.g. Example) in the calculator.
- Note: This copy/paste does not work if you try it in Excel, only in NotePad / WordPad
- Incompatibility with Windows 8.1 high DPI and QHD displays
- Output files in Excel 2013 will have two different formatting (bold/not bold) for the date column on the 'Data' sheet of the file. This is merely a formatting issue and does not affect any of the calculated data.
MagVAR IFR Calculator (MVLM) 4.2.1.1
- File Processing option with input dates in April for DrillingOffice and Weatherford 5D file formats will cause the software to become unresponsive
- Workaround: Delete the "Survey Date:" in the input file header area
- Summary sheet displays m/s2 as units for Gtotal instead of mill-g
- Incompatibility with Windows 8.1 high DPI and QHD displays
- Output files in Excel 2013 will have two different formatting (bold/not bold) for the date column on the 'Data' sheet of the file. This is merely a formatting issue and does not affect any of the calculated data.
MagVAR IFR Calculator (MVLM) 4.2.0
- Incompatibility with Windows 8.1 high DPI and QHD displays
- Summary sheet displays m/s2 as units for Gtotal instead of mill-g
- QC Threshold only allows natural numbers as an input for the sigma multiplier. Fixed in version 4.2.1.1
- Output files in Excel 2013 will have two different formatting (bold/not bold) for the date column on the 'Data' sheet of the file. This is merely a formatting issue and does not effect any of the calculated data.
MagVAR IFR Calculator (MVLM) 4.1.5
- For a point outside the cube, sometimes the calculator shows an irrelevant error message (for both point calculation and file processor). Fixed in version 4.2
- For a point with a date after 1-Jan-2016, the calculator shows an irrelevant error message. Fixed in version 4.2
- Downward gradients values are incorrect when the entered depth is within 10 units from the limits. Fixed in version 4.2
- File processing option breaks if the label for auto-generated contains any of the following characters: \ / ? : [ ] * Fixed in version 4.2
- Incompatibility with Windows 8.1 high DPI and QHD displays
- Output files in Excel 2013 will have two different formatting (bold/not bold) for the date column on the 'Data' sheet of the file. This is merely a formatting issue and does not affect any of the calculated data.